Object Diagnostics¶
When working with systems with a large number of settings, users often have questions about why a particular functionality is not working. Especially for newcomers when the documentation is incomplete and the settings are not obvious (distributed across multiple locations). Traditionally, in such cases, users turn to other users or specialists with questions. Usually, most inquiries end with recommendations to enable a specific setting and check the log for magical strings. As a result, a simple action takes a significant amount of time. To simplify the understanding of the system's operation, the Diagnostics (Diagnostic
) functionality is designed for devices.
Diagnostics - a sequence of checks (Check
) to determine the current use of functionality. The result of the checks can be one of 4 states (State
):
- Enabled - the functionality is successfully used
- Blocked - the functionality is disabled by system settings
- Failed - a failure occurred during the use of the functionality
- Unknown - the functionality is not engaged
User Interface¶
In the user interface of diagnostics, indicators (indicator
) are presented that display the current state. The indicator displays the name of the diagnostics, and the color encodes the states:
- Enabled - green
- Failed - orange
- Blocked - gray
- Unknown - the indicator is not displayed
Diagnostics¶
Diagnostics in the system can be divided into internal - occupied by checking the operation of the system's functions and user - added through the user interface. The difference between them is only in the settings - the first ones are specified in the code, and the second ones are available for modification and are located in the Service Activation -> Setup -> (Object Diagnostic Configuration)
menu.
- Name - the name of the diagnostics. Displayed on the indicator
- Description - description of the diagnostics
- Display Order - priority of indicator display
- Show in form - display the indicator on the device form
- Check Policy
- Any - for success, it is sufficient to pass any check
- All - to succeed, all checks must pass
- Checks - list of checks
- Check - check name
- Argument - parameter for the check. Interpretation depends on the check
- Depends on Diagnostics - dependency on diagnostics. The result of the listed diagnostics will be included in the check
- Launch Parameters
- Run on full discovery
- Run on periodic
- Run Policy
- Always - every poll
- When failed - first time, then on failure
- Run Order
- On start at the beginning of the poll
- On end at the end of the poll
- Alarm Class - raise an alarm on diagnostics failure (transition to the
failed
state) - Alarm Labels - add labels to the alarm
- Save in History - save the results of checks in history
- Device Check Rules - allow specifying on which devices to run diagnostics
Note
For diagnostics launched at the end of polling: if an error occurs at the previous stage, the diagnostics will not be started!
Built-in Diagnostics¶
The system already includes several diagnostics that are launched at the start of full discovery (Box Discovery
) and check the operation with equipment.
PROFILE¶
Checks the correctness of the SA Profile
selection for the device. Settings:
- The
Profile
checkbox in the object profile settings enables/disables diagnostics - Profile check rules are in (
Profile Check Rules
)
SNMP¶
Checks the access credentials for SNMP. Can use multiple access credentials when access rules are available. Settings:
- Access preference priority. If
Access Preference - CLI Only
, diagnostics are blocked - Allow access credentials selection. Allows the use of access credential selection rules during access setup
CLI¶
Checks the access credentials for TELNET/SSH. Can use multiple access credentials when access rules are available. Settings:
- Access preference priority. If
Access Preference - SNMP Only
, diagnostics are blocked - Allow access credentials selection. Allows the use of access credential selection rules during access setup
Access¶
Comprehensive diagnostics include CLI
, SNMP
, and HTTP
. To work correctly, all incoming access protocols are required.
SNMPTRAP and SYSLOG¶
Sets the fact of receiving an SNMP Trap
or Syslog
for the device. It triggers when the first SNMP Trap or Syslog is received from the device. Settings:
- Syslog/Trap source in device settings
Event Process Policy
in device or object profile settings
Table of built-in diagnostics settings
Name | Run Policy | Checks | Alarm Class |
---|---|---|---|
PROFILE | Unknown or Failed | PROFILE | Discovery | Guess | Profile |
SNMP | Unknown or Failed | SNMPv1, SNMPv2c | NOC | Managed Object | Access Lost |
CLI | Unknown or Failed | TELNET, SSH | NOC | Managed Object | Access Lost |
Access | --- | SNMP, CLI | NOC | Managed Object | Access Degraded |
SNMPTRAP | --- | --- | --- |
SYSLOG | --- | --- | --- |
Checks¶
Diagnostics are implemented through checks. The system includes several checks:
- REMOTE_PING - Check the availability of the IP address from the device. Requires the ping script to be implemented.
- SNMPv1, SNMPv2c - Check the
SNMP
access credentials. Uses credentials from the device settings. - TELNET, SSH - Check the
CLI
access credentials forTELNET
andSSH
. Uses credentials from the device settings. - PROFILE - Check the device profile based on the rules from the menu.
- LOCAL_PING - Check the availability of the IP address from the NOC (activator).
In addition to the built-in checks, users can add custom ones. To do this, it is necessary to connect the custom one and place the code in core/checkers